Zion Code and Description
Zion Code |
Zion Description |
7216060 |
10G SFP+ TO SFP+ Active Optical Cable |
Applications
- 25GBASE-SR4 100G Ethernet Links; InfiniBand QDR applications
- Servers, switches, storage and host card adap
Description
The 7216060 10G SFP+ active optic cables are a high performance, low power consumption,
long reach interconnect solution supporting 10G Ethernet ,or Infini BandQDR/DDR/SDR,
12.5G/10G/8G/4G/2G fiber channel ,PCIe and SAS.
It is specially designed for high-speed, short-range data links via optical fiber lines.
SFP+ AOC provides signal integrity, longer distance, superior electromagnetic immunity
and better bit error rate. It is a cost-effective solution for data center/storage
and all short-range data applications.
Main product parameters
Connector Type |
SFP+ to SFP+ |
Vendor Name |
Zion Communication |
Max Data Rate |
10Gbps |
Fiber cable Type |
MMF |
Max Cable Distance 1 |
70m on OM3 MMF |
Max Cable Distance 2 |
100m on OM4 MMF |
Transimitter Type |
VCSEL |
Receiver Type |
PIN |
Wavelength |
850nm |
CDR |
Support |
Power Supply |
3.3V |
Operating Temp. |
0°C to 70°C (32°F to 158°F) |
Outline Drawing

Zion Code |
Zion Description |
7216010 |
100G QSFP28 TO QSFP28 Active Optical Cable |
7216020 |
100G QSFP28 TO 4×SFP28 Active Optical Cable |
7216030 |
40G QSFP+ TO QSFP+ Active Optical Cable |
7216040 |
40G QSFP+ TO 4×SFP+ Active Optical Cable |
7216050 |
25G SFP28 TO SFP28 Active Optical Cable |
7216060 |
10G SFP+ TO SFP+ Active Optical Cable |
Read More
Electrical Performance
1. Absolute Maximum Ratings
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
|
Storage Temperature (℃) |
TS |
-10 |
|
70 |
°C |
|
Relative Humidity |
RH |
5 |
|
85 |
% |
|
Power Supply Voltage |
VCC |
-0.5 |
|
3.6 |
V |
|
2. Recommended Operating Environment
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Note |
Case operating Temperature |
TOP |
0 |
|
70 |
°C |
|
Power Supply Voltage |
VCC |
3.14 |
3.3 |
3.47 |
V |
|
Power Dissipation |
Pd |
|
|
0.6 |
W |
|
Data Rate |
BR |
|
10.3125 |
|
Gbps |
Each Channel |
Transmission Distance with |
TD |
0 |
|
100 |
m |
OM4 |
3. Electrical Characteristics for SFP+
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Transmitter |
Differential data input swing |
Vin.pp |
200 |
|
1000 |
mV |
Input Differential Impedance |
ZD |
90 |
100 |
110 |
Ω |
Tx_Fault |
Normal Operation |
VOL |
0 |
|
0.8 |
V |
Transmitter Fault |
VOH |
2 |
|
Vcc+0.3 |
V |
Tx_Disable |
Normal Operation |
VIL |
0 |
|
0.8 |
V |
Laser Disable |
VIH |
2 |
|
Vcc+0.3 |
V |
Receiver |
Differential data output swing |
Vin.pp |
200 |
|
800 |
mV |
Bit Error Rate (1 prbs2^31-1@25.78125Gbps) |
BER |
|
|
E-12 |
|
Input Differential Impedance |
Zin |
90 |
100 |
110 |
Ω |
Rx_LOS |
Normal Operation |
VOL |
0 |
|
0.8 |
V |
Lose Signal |
BER |
2 |
|
Vcc+0.3 |
V |
4. Pin Assignment

5. Pin description
Pin |
Symbol |
Name/Description |
NOTE |
1 |
VEET |
Transmitter Ground (Common with Receiver Ground) |
1 |
2 |
TFAULT |
Transmitter Fault. |
2 |
3 |
TDIS |
Transmitter Disable. Laser output disabled on high or open. |
3 |
4 |
SDA |
2-wire Serial Interface Data Line |
4 |
5 |
SCL |
2-wire Serial Interface Clock Line |
4 |
6 |
MOD_ABS |
Module Absent. Grounded within the module |
4 |
7 |
RS0 |
Rate Select 0 |
5 |
8 |
LOS |
Loss of Signal indication. Logic 0 indicates normal operation. |
6 |
9 |
RS1 |
No connection required |
1 |
10 |
VEER |
Receiver Ground (Common with Transmitter Ground) |
1 |
11 |
VEER |
Receiver Ground (Common with Transmitter Ground) |
1 |
12 |
RD- |
Receiver Inverted DATA out. AC Coupled |
|
13 |
RD+ |
Receiver Non-inverted DATA out. AC Coupled |
|
14 |
VEER |
Receiver Ground (Common with Transmitter Ground) |
1 |
15 |
VCCR |
Receiver Power Supply |
|
16 |
VCCT |
Transmitter Power Supply |
|
17 |
VEET |
Transmitter Ground (Common with Receiver Ground) |
1 |
18 |
TD+ |
Transmitter Non-Inverted DATA in. AC Coupled. |
|
19 |
TD- |
Transmitter Inverted DATA in. AC Coupled. |
|
20 |
VEET |
Transmitter Ground (Common with Receiver Ground) |
1 |
Note:
1.Circuit ground is internally isolated from chassis ground.
2.TFAULT is an open collector/drain output, which should be pulled up with a 4.7kΩ– 10 kΩ resistor on the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V.A high output indicates a transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the output is pulled to <0.8V.
3.Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
4.Should be pulled up with 4.7kΩ- 10kΩ on host board to a voltage between 2.0V and 3.6V. MOD_ABS pulls line low to indicate module is plugged in.
5.Internally pulled down per SFF-8431 Rev 4.1.
6.LOS is open collector output. It should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V.
Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Download